Is $1,150 to repair a leaking Rheem AC condenser coil a fair price?
Project Details
My Rheem 2-ton, 14 SEER AC unit (model RA14AZ24AJ1NALHP), which was installed less than two years ago, is leaking refrigerant from the outside condenser coil. The unit has a 10-year parts warranty but only a 1-year labor warranty, which has expired. The original installation cost was around $6,000. I'm concerned about the quality of the unit, as my previous 13-year-old AC never leaked. The technician suggested it might be due to "weak copper" and not an installation issue. I'm wondering if this quote is reasonable and if the coil will just leak again.
Quote Details
This quote is for the repair of a leaking outside condenser coil on a Rheem 2-ton, 14 SEER AC unit (model RA14AZ24AJ1NALHP). The condenser coil part is covered under warranty, but the quote covers other necessary services and materials. - Condenser coil: Parts covered under warranty - Refrigerant recovery - Filter dryer - R410 refrigerant: Up to 10 lbs
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$1,150
Quote Date
August 21, 2025
Location
Florida
Brand/model
Rheem RA14AZ24AJ1NALHP
BTU tonnage
2 Ton
Efficiency rating
14 SEER
Fuel type
Electric
System type
Air conditioner
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Replace a leaking R-410A coil under warranty
This quote is for a warranty coil replacement due to a leaking R-410A coil. The service includes: - All labor for the replacement - Refrigerant (for a 1.5-ton condenser) - All necessary materials - Warranty processing fees
Replace AC condenser coil and recharge refrigerant
This quote is for the repair of a Carrier Model CA15NA036-A residential AC unit that has a significant leak in its condenser coils, resulting in almost no coolant remaining. The condenser coil itself is covered under warranty and will be fully replaced. - AC Unit Model: Carrier CA15NA036-A - Issue: Leak in condenser coils, almost no coolant left - Coil Status: Under warranty, full replacement included - Services Included: Labor for coil replacement, refrigerant charge - Refrigerant Type: R410 - Refrigerant Quantity: 6.4 lbs (factory charge) - Diagnosis: Leak confirmed via nitro test