chippyo

Is $3,500 to perform a nitrogen pressure test to find leaks and replace refrigerant a fair price?

Project Details

I have a 14-year-old Lennox 4-ton HVAC system. I'm getting a 411 code indicating low pressure on the outdoor unit, which I suspect is due to low refrigerant. A technician inspected my indoor unit and found rust on the coil, which appears to be leaking into the area of the motor and control boards.

Quote Details

- Perform nitrogen pressure test to find leaks in the HVAC system.- Replace refrigerant.

Thank you for your feedback!

You say...

?
How would you rate this quote?
TooCheap
GoodDeal
FairPrice
BitPricey
Ripoff

Vote Distribution

Too Cheap0 votes
Good Deal0 votes
Fair Price0 votes
Bit Pricey0 votes
Ripoff1 votes

These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.

More Details

Category

HVAC

Price

$3,500

Quote Date

August 20, 2025

Comments

No comments yet

Sign in to share your thoughts and ask questions.

Similar Quotes

Map of 85044
Arizona
HVAC
$7,409
Jun 4, 2025

Perform comprehensive HVAC system repair and maintenance

This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.

2 ratings3 comments
HVAC
$600
May 30, 2025

Perform a nitrogen leak test

A nitrogen leak test to detect refrigerant leaks.

1 rating
HVAC
$2,000
May 20, 2025

Perform a nitrogen leak test on a 3 ton AC unit

Quote for a detailed nitrogen leak test to locate a refrigerant leak in a 3-ton AC unit. - Service: Detailed nitrogen leak test - Purpose: Locate refrigerant leak - Equipment: 3-ton AC unit (indoor and outdoor units) - Unit Age: Less than 5 years old - Warranty: Under manufacturer's parts warranty (Amana)