Is $700 to replace furnace control board a fair price?
Project Details
My Trane XL 80 furnace is showing a high limit switch warning (LED blinks 4 times). An HVAC technician visited twice; on the first visit, he changed the pressure switch and said the furnace was too old. On the second visit, he suggested replacing the control board for $700 and also gave quotes for a new furnace, but I'm skeptical of his diagnosis and methods. He didn't check for common issues like clogged air filters or blocked registers. I've since changed the air filters. The furnace sometimes works but mostly shuts down after initial ignition, with no air from registers. My AC works fine.
Quote Details
The HVAC technician diagnosed a high limit switch warning (LED blinks 4 times) on a Trane XL 80 furnace and recommended the following: - Replace control board
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$700
Quote Date
November 27, 2025
Brand/model
Trane XL 80
System type
Furnace
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Replace the circuit board on a Trane furnace
This quote is for replacing the control board of a 15-year-old Trane furnace, model TUH2C100A9V4VA. The existing control board was diagnosed as not sending power to the inducer motor, causing the furnace to turn off.

Replace a furnace control board
Replacement of the furnace control board for a Rheem furnace. - Diagnosis: Technician observed igniter flashing for a fraction of a second before system shutdown. - Troubleshooting: Technician tested with a different igniter, but the issue persisted. - Conclusion: Technician determined the control board was 'acting funny' and was the cause of the malfunction.