Is $2,000 to enlarge the return ductwork a fair price?
Project Details
I have an about 17-year-old rooftop HVAC unit (R-22 refrigerant) that I had serviced this summer. The techs brought up issues on both the furnace and AC side. For the AC, they said the superheat is too low and the subcooling is low, indicating potential problems with liquid refrigerant returning to the compressor and a small reserve of extra-cooled liquid. They also mentioned my furnace's heat exchanger is discoloring and might crack, though I'm skeptical of immediate danger. The tech notes also indicated elevated static pressure due to undersized ductwork, a blower capacitor below manufacturer specification, and low R-22 refrigerant pressures suggesting a leak or failing metering device. My unit has been working fine all summer, and it's a 2009 Goodman 2-ton single-stage rooftop unit that has been serviced twice a year for several years. The quote for replacement recommended going up to a 2.5 or 3-ton unit due to the house's southwest exposure.
Quote Details
This quote is for improving the airflow of my HVAC system by enlarging the return ductwork. This work is intended to address several existing issues: - Elevated static pressure caused by undersized return and supply ductwork. - Refrigerant pressure issues (low superheat and subcooling) which could lead to liquid refrigerant returning to the compressor. - Potential issues with the furnace's heat exchanger, which is showing discoloration and might crack.
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$2,000
Quote Date
October 2, 2025
System type
Furnace, Air conditioner
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty

Rework ductwork to increase air intake
The HVAC technician suggested reworking the ductwork because the current unit/furnace is oversized for the existing ductwork, which is adding strain to the system. The proposed work aims to increase air intake. - Rework existing ductwork to increase air intake