Is $4,250 to replace mnet power board, controller board, power board and fuses a fair price?
Project Details
I have a 2019 Mitsubishi Heat Pump system (MXZ-8C48NA) that some rodent built a nest in over winter. When I turned on the heat once temperatures got warmer, it fried some boards in the outdoor unit. I can get the boards for about $1500 through a family friend (does commercial hvac).
Quote Details
Repair of 2019 Mitsubishi Heat Pump system (MXZ-8C48NA) damaged by rodent nesting. - Replace MNET power board - Replace controller board - Replace power board - Replace fuses for power board
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$4,250
Quote Date
May 23, 2026
Brand/model
Mitsubishi MXZ-8C48NA
BTU tonnage
4 Ton
Fuel type
Electric
System type
Heat pump
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.

Replace circuit board and thermistor in mini split system
This quote is for the repair of a mini split system that has been damaged by rodents. - Circuit board replacement - Thermistor replacement