chippyo

Is $3,500 to replace or repair the evaporator coil a fair price?

Project Details

My evaporator coil is leaking. I am fairly handy and have done many DIY projects, including replacing my car's clutch, and I'm considering replacing the entire AC system myself. I found a complete system online for $5,700, including the furnace. My current unit is in the attic, so I anticipate needing more refrigerant than what comes with a new system. I have a friend with an HVAC contact who can handle the refrigerant filling and related tasks. I'm trying to understand the actual difficulty, tool costs, and time commitment for a DIY replacement versus paying for labor. I plan to get another quote from my buddy's HVAC contact. If I do it myself, I would use an R410a system and reuse the existing air circulation/ductwork.

Quote Details

This quote is for the replacement or repair of the existing evaporator coil, which has been determined to be leaking.

Thank you for your feedback!

You say...

?
How would you rate this quote?
TooCheap
GoodDeal
FairPrice
BitPricey
Ripoff

Vote Distribution

Too Cheap0 votes
Good Deal0 votes
Fair Price0 votes
Bit Pricey0 votes
Ripoff1 votes

These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.

More Details

Category

HVAC

Price

$3,500

Quote Date

June 10, 2025

System type

Air conditioner

Comments

No comments yet

Sign in to share your thoughts and ask questions.

Similar Quotes

Map of 85044
Arizona
HVAC
$7,409
Jun 4, 2025

Perform comprehensive HVAC system repair and maintenance

This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.

2 ratings3 comments
Map of 10804
New York
HVAC
$8,300
Jun 4, 2025

Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room

- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty

1 rating1 comment
HVAC
$3,400
Jun 10, 2025

Replace the evaporator coil

The quote is for replacing the evaporator coil due to a refrigerant leak. - Service: Evaporator coil replacement - Refrigerant: R410a refrigerant included

1 rating