Is $23,575 to install a 2-ton lennox dual fuel system with new ductwork a fair price?
Project Details
Upgrading from electric baseboards with $700/month winter bills. Electric rate is $0.27/kWh and propane is around $3-4/gallon. Planning to switch from heat pump to gas backup at 30 degrees.
Quote Details
Full HVAC installation including a Lennox EL18KSLV heat pump and Lennox ML180 furnace. - Lennox EL18KSLV 2-ton variable capacity heat pump (SEER2 16.2, HSPF2 8.5) - Lennox ML180 80% AFUE single stage furnace (66k BTU) - New ductwork package including trunk, supplies, and returns (up to 8 runs) - New electrical disconnect, whip, and pad - New venting, gas piping, and condensate lines - Ecobee thermostat and MERV 11 filter - 10-year parts and labor warranty - R-454B refrigerant (2025 compliant)
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$23,575
Quote Date
April 8, 2026
Location
Connecticut
Home Size
1,200 sq ft
Brand/model
Lennox EL18KSLV, Lennox ML180
BTU tonnage
2-ton, 66,000 BTU
Efficiency rating
SEER2 16.2, 80% AFUE
Fuel type
Natural gas
Labor warranty
10
Parts warranty
10
System type
Furnace, Heat pump
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Install a Lennox dual fuel HVAC system
This estimate is for the installation of a new 4 ton 18 SEER2 variable capacity cold climate heat pump as well as a 110k btu single stage 80% gas furnace. The installation includes: - New furnace - Short riser box - Replacing the return drop with 10x25 duct - Adding guillotine filter location - Disconnecting lower trunk line and capping the duct - Adding 2-10" duct runs to connect to supply plenum - Adding turning vanes into the supply and return in 4 locations to improve airflow and system performance - New condensate pump - Moving outdoor condenser over 5' to wider window opening - Extending the lineset to that area - Outdoor equipment pad with risers - Customer to run larger electrical circuit from adjacent breaker panel - Lennox E30 thermostat - Removal and disposal of the old equipment - Complete system start up - All taxes, labor, and materials - Warranty: 10 year parts, 20 year heat exchanger - Maintenance: First year included, up to 3 year labor warranty with continued maintenance