Is $21,000 to replace the entire combination boiler system a fair price?
Project Details
I have an awful combination Navian boiler system that has caused endless headaches. It's a tankless water heater connected to a storage tank, providing water heating and radiant heating for my townhome. Every technician has called out how problematic the system is. I've been working with two companies, Radiant Heating technicians and a certified plumbing company, on repairs. I've had yearly maintenance done. In May 2024, hot water issues led to replacing an inlet filter, leaking isolation cap, ignitor seal, and fixing a condo line. In February 2025, maintenance included wiring the boiler to a circuit, replacing two failing expansion tanks, setting the boiler expansion tank to ~15psi, adding an isolation drain valve, and noting high home pressure (100psi). Seals on the pump also began leaking after repressurizing. In March 2025, a certified plumber fixed the high pressure by replacing/upgrading the pressure reduction valve (PRV) with a brass diaphragm, calibrating it to maintain pressure just under 80 psi, and re-pressurizing the domestic thermal expansion tank. They also noted that the expansion tanks installed by the previous technicians seemed incorrect. In June 2025, I noticed a thumping/whirring sound when hot water was used. The certified plumber diagnosed a frozen Armstrong pump and a frozen recirculation pump. They recommended replacing the entire system. I'm calling the radiant heat technicians back to see if their work contributed to the problem, and I'm seeking input on whether I need to replace the entire system, who should do it, and what exactly should be replaced.
Quote Details
This quote is for replacing the entire combination boiler system. The existing system is a Navian combination boiler that functions as a tankless water heater connected to a storage tank, providing both domestic hot water and radiant heating for the townhome. The replacement is recommended due to ongoing issues, including frozen Armstrong and recirculation pumps. - System Type: Combination Navian boiler system - Components: Tankless water heater, Storage tank, Armstrong pump, Recirculation pump - Function: Domestic hot water and radiant heating
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$21,000
Quote Date
June 1, 2025
Brand/model
Navian
System type
Boiler
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes

Replace a 75 gallon natural gas power vented water heater
This quote includes the supply and installation of a new 75-gallon natural gas power vented water heater, along with all necessary piping and fittings. - Water Heater Type: 75 gallon natural gas power vented - Included Components: Mixing valve, Expansion tank - Piping Material: 3/4 copper - Fittings: All 3/4 fittings needed to assemble the water heater correctly
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty