Is $650 to replace rusted furnace vent connector pipe a fair price?
Project Details
I am a homeowner trying to determine the best course of action to correct what appears to be a condensation issue in my furnace vent connector pipe. I recently had the b vent cleaned and inspected by a chimney sweeping company. The b vent is all in great shape, but they found the connector pipe to be completely rusted inside and there is what they described as efflorescence in the connector. There has also been what I now know is broken up rust and the same efflorescence looking material on top of the furnace cabinet. My furnace is a 2 stage, 80% Ruud, installed in 2019, with a minimum BTU of 52,500 and a maximum BTU of 75,000. It is currently the only appliance using this vent system. My house is a 2 story home with a conditioned basement and attic. From the furnace, there is currently a single wall vent pipe that connects to the inducer fan outlet. The fan outlet is 3” diameter that has an increaser to 4”. This 4 inch connector pipe is about 20 inches before an elbow, which then goes to a Y pipe that increases from 4” to 5” before tying in to the main vent. The main vent is 5” b vent, starting from the connector pipe has a 6 foot horizontal run to an elbow. From this elbow it runs from the basement through the roof. This vertical run is approximately 27-30 feet. I do not believe the chimney company's proposal will actually solve anything after reading up on venting sizing tables. The HVAC company does not believe there is an issue and recommended swapping out the vent connector for new. I am wondering what the best solution is. Technically, it looks as if my entire b vent should be replaced with 4 inch b vent, but I am wondering if a safe and reasonable alternative would be to replace the current single wall connector pipe with 4 inch b vent pipe. Neither company thinks the double wall vent is necessary, but it seems like that is the appropriate material for this job. I am also wondering if changing the current horizontal 5 inch b vent to 4 inch b vent would help reduce the risk of condensation even further.
Quote Details
The chimney company's proposal to correct the condensation issue in the furnace vent connector pipe: - Remove: Current rusted out connector pipe - Replace with: New single wall 4 inch pipe - Connection: Direct 4 inch adapter from inducer motor (as specified in the furnace's installation manual), replacing the existing increaser - Expected Outcome: Slow cooling of the vent system and reduce condensation
You say...
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$650
Quote Date
November 12, 2025
System type
Furnace
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes

Install 3-inch vent pipes for furnace
This quote is for replacing the existing 2-inch PVC vent pipes with 3-inch pipes for a Bryant Model: 926TB60100V21A-B furnace. - Furnace Specifications: 100,000 BTU, 96% efficiency - Current Vent Pipe Size: 2-inch PVC - Proposed Vent Pipe Size: 3-inch - Current Pipe Configuration: 1-90 degree elbow, 2-medium 90 degree elbows, 1-long sweep 90 degree elbow, 4-45 degree elbows, 14 feet of 2-inch pipe - Problem Addressed: Furnace displaying 3-3 or 1-3 error codes in cold weather due to undersized vent pipes, as diagnosed by an HVAC technician

Replace heater chimney vent system with new B-vent
Estimate for the complete removal and replacement of the heater chimney vent system. - Complete removal of original heater chimney vent system and components - Replacement with new B-vent system - Address deterioration and cracking in the chimney - Correct improper venting through the b-vent tee - Ensure proper draft

Replace flue pipe and install new chimney
This quote is representative of proposals from four different chimney companies, with prices ranging from $4,800 to $5,200. They all suggested replacing the entire flue pipe and installing a new chimney at the top of the roof. - Flue Pipe: Replacement of the entire flue pipe (estimated 7-inch galvanized steel) - Scope: Work extends up through the roof - Scope: Installation of a new chimney at the top