Is $900 to install 3-inch vent pipes for furnace a fair price?
Project Details
I have been getting a 3-3 or 1-3 error code on my Bryant Model: 926TB60100V21A-B furnace when it gets really cold outside, around 20 degrees. The current vent pipes are 2-inch PVC, and the outlet pipe looks narrowed. An HVAC technician diagnosed the problem as incorrect furnace installation due to undersized vent pipes. This issue has been occurring since I moved into the house two years ago, causing the furnace to lock out for a few hours once a day. I'm also curious why there is a reducer in the current setup. The furnace is located in an open basement.
Quote Details
This quote is for replacing the existing 2-inch PVC vent pipes with 3-inch pipes for a Bryant Model: 926TB60100V21A-B furnace. - Furnace Specifications: 100,000 BTU, 96% efficiency - Current Vent Pipe Size: 2-inch PVC - Proposed Vent Pipe Size: 3-inch - Current Pipe Configuration: 1-90 degree elbow, 2-medium 90 degree elbows, 1-long sweep 90 degree elbow, 4-45 degree elbows, 14 feet of 2-inch pipe - Problem Addressed: Furnace displaying 3-3 or 1-3 error codes in cold weather due to undersized vent pipes, as diagnosed by an HVAC technician
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$900
Quote Date
November 29, 2025
Brand/model
Bryant 926TB60100V21A-B
BTU tonnage
100,000 BTU
Efficiency rating
96% efficiency
System type
Furnace
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes

Replace a 75 gallon natural gas power vented water heater
This quote includes the supply and installation of a new 75-gallon natural gas power vented water heater, along with all necessary piping and fittings. - Water Heater Type: 75 gallon natural gas power vented - Included Components: Mixing valve, Expansion tank - Piping Material: 3/4 copper - Fittings: All 3/4 fittings needed to assemble the water heater correctly

Replace rusted furnace vent connector pipe
The chimney company's proposal to correct the condensation issue in the furnace vent connector pipe: - Remove: Current rusted out connector pipe - Replace with: New single wall 4 inch pipe - Connection: Direct 4 inch adapter from inducer motor (as specified in the furnace's installation manual), replacing the existing increaser - Expected Outcome: Slow cooling of the vent system and reduce condensation
Replace a furnace vent pipe
The quote is for replacing a furnace vent pipe due to a detected low amount of carbon monoxide when starting the furnace. - Scope: Replace furnace vent pipe (up to 3 pieces)