Is $1,000 to replace TXV valve and recharge AC refrigerant a fair price?
Project Details
I have an older (20-25 years) Rheem Classic Series central AC unit that recently tripped a breaker and started blowing warm air. I've also heard clattering and creaking fan noises. I have an AHS warranty policy, but it only covers a small portion of the refrigerant cost and doesn't cover the TXV valve replacement, leading to a $1000 estimate. I'm frustrated because I've paid for this policy for a decade and feel it should cover more, or ideally, a full unit replacement. The warranty company stated that replacement is only an option if the part is unavailable, not due to wear and tear or age. I'm looking for advice on how to advocate for a full unit replacement, especially considering the policy's clause about covering upgrades for energy compliance. The technician was not very helpful or friendly. I'm trying to understand if a bad TXV valve could cause refrigerant leaks or noises.
Quote Details
This quote is for addressing a TXV valve failure due to normal wear and tear, which is causing the AC unit to not cool properly. The work includes: - Replace TXV valve - Recharge AC refrigerant (Freon) - AC Unit: Older Rheem Classic Series central AC unit (estimated 20-25 years old)
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$1,000
Quote Date
October 2, 2025
Brand/model
Rheem Classic Series
System type
Air conditioner
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Replace a bad TXV valve and recharge AC system
This quote is for the repair of an older 2-ton Trane R-22 AC system, which includes replacing a faulty TXV valve and recharging the system with 407C refrigerant. The initial issue was the compressor not running due to overheating and low refrigerant, which also burned out the capacitor. The technician diagnosed a low refrigerant level and a "toast" TXV valve that was stuck open, preventing a simple recharge with R-22. - Scope of Work: Replace bad TXV valve- Refrigerant: Recharge with 5 lbs of 407C- System Type: Older 2-ton Trane R-22 AC system- Initial Problem: Compressor not running, shut off due to overheat/low refrigerant, burnt capacitor- Diagnosis: Low refrigerant, TXV valve stuck open (preventing R-22 recharge)

Replace a TXV valve and address a refrigerant leak
The quote covers the replacement of a TXV valve, which is under warranty. The total cost of $1750 includes the following services and charges: - TXV valve replacement (under warranty) - Refrigerant - Visit fees (including a second visit to find the leak) - Leak test