Is $2,800 to replace a TXV valve a fair price?
Project Details
My AC was installed recently, but it's underperforming. It was installed 1 year ago, but I only started using it 2 months ago when the heat began. The technician says I need to replace the TXV valve. I don't have a warranty on it. I'm concerned that changing the valve might not solve the problem. The AC is only cooling 10 degrees from return to supply, and the technician said the normal temperature difference should be between 15 to 20 degrees. The indoor temperature at the AC return was 75 degrees.
Quote Details
The technician diagnosed the AC system and found that the liquid line is colder than the suction line, indicating a restriction, most likely a failed TXV (thermostatic expansion valve). The proposed work includes: - Recover existing refrigerant (R-410A or as applicable) - Replace the TXV on the indoor coil - Pressure test and evacuate system - Recharge refrigerant to manufacturer specifications - Seal return and supply plenum to improve system performance and efficiency - Perform system startup and verify proper superheat and subcooling
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$2,800
Quote Date
June 12, 2025
Fuel type
Electric
System type
Air conditioner
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty

Replace a TXV valve
Replacement of the Thermostatic Expansion Valve (TXV) due to a diagnosis of a struggling HVAC system. The technician stated that a faulty TXV valve would cause the observed symptoms.