replace a TXV valve
Photo 1

Is $2,800 to replace a TXV valve a fair price?

Project Details

My AC was installed recently, but it's underperforming. It was installed 1 year ago, but I only started using it 2 months ago when the heat began. The technician says I need to replace the TXV valve. I don't have a warranty on it. I'm concerned that changing the valve might not solve the problem. The AC is only cooling 10 degrees from return to supply, and the technician said the normal temperature difference should be between 15 to 20 degrees. The indoor temperature at the AC return was 75 degrees.

Quote Details

The technician diagnosed the AC system and found that the liquid line is colder than the suction line, indicating a restriction, most likely a failed TXV (thermostatic expansion valve). The proposed work includes: - Recover existing refrigerant (R-410A or as applicable) - Replace the TXV on the indoor coil - Pressure test and evacuate system - Recharge refrigerant to manufacturer specifications - Seal return and supply plenum to improve system performance and efficiency - Perform system startup and verify proper superheat and subcooling

Thank you for your feedback!

You say...

?
How would you rate this quote?
TooCheap
GoodDeal
FairPrice
BitPricey
Ripoff

Vote Distribution

Too Cheap0 votes
Good Deal0 votes
Fair Price0 votes
Bit Pricey0 votes
Ripoff1 votes

These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.

More Details

Category

HVAC

Price

$2,800

Quote Date

June 12, 2025

Fuel type

Electric

System type

Air conditioner

Comments

No comments yet

Sign in to share your thoughts and ask questions.

Similar Quotes

Map of 85044
Arizona
HVAC
$7,409
Jun 4, 2025

Perform comprehensive HVAC system repair and maintenance

This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.

2 ratings3 comments
Map of 10804
New York
HVAC
$8,300
Jun 4, 2025

Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room

- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty

1 rating1 comment
replace a TXV valve
HVAC
$1,300
Aug 11, 2025

Replace a TXV valve

Replacement of the Thermostatic Expansion Valve (TXV) due to a diagnosis of a struggling HVAC system. The technician stated that a faulty TXV valve would cause the observed symptoms.

1 rating