Is $1,300 to replace a TXV valve a fair price?
Project Details
Last week, a technician replaced a UV bulb in my system. Before that, I had no issues other than the UV light being out. The day after the UV bulb replacement, my system started struggling and slowly loses cooling capacity as it gets hotter. A technician from the same company came today, looked at the unit coils, and diagnosed a faulty TXV valve. I'm questioning this diagnosis because I suspect I might be low on coolant, especially since the copper pipe going from outside into the house is barely cold. I'm getting a second opinion from another company tomorrow.
Quote Details
Replacement of the Thermostatic Expansion Valve (TXV) due to a diagnosis of a struggling HVAC system. The technician stated that a faulty TXV valve would cause the observed symptoms.
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$1,300
Quote Date
August 11, 2025
System type
Air conditioner, Heat pump
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Replace a TXV
This quote is for the replacement of a Thermostatic Expansion Valve (TXV). The technician diagnosed the issue by putting on gauges, which indicated a clogged system. An attempt to unclog the system by adding refrigerant was unsuccessful. The quoted cost does not include any additional refrigerant that may be required.

Replace a TXV valve
The technician diagnosed the AC system and found that the liquid line is colder than the suction line, indicating a restriction, most likely a failed TXV (thermostatic expansion valve). The proposed work includes: - Recover existing refrigerant (R-410A or as applicable) - Replace the TXV on the indoor coil - Pressure test and evacuate system - Recharge refrigerant to manufacturer specifications - Seal return and supply plenum to improve system performance and efficiency - Perform system startup and verify proper superheat and subcooling