Is $1,474 to replace a TXV in an AC system a fair price?
Project Details
My A/C went out last Friday, and a tech came to check it on Monday. My house doesn't have a basement, only a crawl space to access the A/C and furnace, which I know is difficult to maneuver. After inspection, the tech informed me the TXV was completely closed and needed replacement. I initially expected the cost to be less than $800 to $1,000, especially since the part itself is only $329. I'm a new homeowner and don't know much about HVAC. I'm getting a second opinion tomorrow. My crawl space is set up terribly, and I hate being down there.
Quote Details
This quote is for the replacement of a TXV (Thermostatic Expansion Valve) in an AC system, including various associated services. The work involves accessing the AC and furnace through a crawl space. - TXV: $329.99 - Condenser cleaning: $150 - Indoor coil cleaning: $150 - Refrigerant recovery process: $125 - Nitrogen pressure test: $75 - Evacuation of system: $99 - Refrigerant charging & balancing process: $125 - Labor (3 hours): $420
You say...
Vote Distribution
These ratings are not endorsed by Quote Critic. They are submitted by other Quote Critic users like you.
More Details
Category
HVAC
Price
$1,474
Quote Date
June 25, 2025
Location
Michigan
System type
Air conditioner, Furnace
Comments
No comments yet
Sign in to share your thoughts and ask questions.
Similar Quotes
Perform comprehensive HVAC system repair and maintenance
This quote covers a comprehensive set of HVAC services, including: - Uninstallation and disposal of the old damaged coil. - Leak free installation of the new coil. - Full system testing and calibration for peak performance. - Uninstallation and disposal of the old damaged filter drier. - Leak free installation of the new filter drier. - Full system testing and calibration for peak performance. - Refrigerant leak detection. - Recover refrigerant. - Nitrogen purge. - Leak repair. - Pressure test. - All refrigerant recovery and recycling following EPA protocol. - Purging refrigerant lines with dry nitrogen. - Accurate refrigerant weigh in/out with calibrated scale. - Complete refrigerant testing for peak system operation using super heat and sub cooling diagnostics. - Adding refrigerant to EPA guidelines. - Remove schrader core with isolation tool. - Install new schrader core and new cap. - Leak test service valve.
Install Mitsubishi 9KBTU Hyperheat Mini Split Heat Pump System for one room
- Perform manual J Load calculation to understand true heating and cooling loads for the area of house served by the furnace - Furnish and install new Heatpump system consisting of Outdoor Unit and Wall Mounted Indoor Unit - Furnish and install Refrigerant piping, interlock wiring and drain tubing - Furnish and install Linehide to cover refrigerant , drain and wire - Furnish and install Condenser Pad - Start up and check test of operation - 1 year labor warranty - 12 year limited manufacturer’s parts warranty

Replace indoor TXV valve
This quote is for the replacement of an indoor TXV valve. - Recovery of existing refrigerant - Installation of new TXV valve - Filter dryer replacement - Pressure test - Vacuum system - Recharge with new refrigerant - Lead time on part: 1-3 days